Owner’s manual, Compressor (cont’d) trouble shooting (cont’d) – Steele Products SP-CE043 User Manual

Page 27

Advertising
background image

27

Owner’s Manual

Compressor (cont’d)

TROUBLE SHOOTING (cont’d)

Overheating

• Poor ventilation

Relocate compressor to an area with cool, dry and well-circulated air.

• Dirty cooling surface

Clean all cooling surfaces of pump thoroughly.

• Leaking valve

Replace worn parts and reassemble with new seals.

Motor stalls

• Low voltage

Furnish adequate power.

• Defective pressure switch bleeder valve

Replace pressure switch bleeder valve.

Pressure relief valve opens

• Tank pressure exceeded normal operating pressure

Replace pressure switch

Motor will not run

• Tank pressure exceeds present pressure switch limit

Motor will start automatically when tank pressure drops below kick-in pressure tank.

• Motor overload protection has tripped

Let motor cool off and overload switch will automatically reset. This may take several

minutes.

Advertising