Cleaning instructions, Cleaning instructions maintenance instructions – L.B. White AW100 User Manual

Page 13

Advertising
background image

WARNING

This heater may be washed only on the external case

assembly provided:

A.

The heater is disconnected from the electrical

supply.

B. All access panels are securely closed.

C. Water spray nozzle shall not discharge within 6 feet

of the heater.

D. The water pressure does not exceed 45 PSIG for 10

seconds on each side of heater.

E.

The heater is not reconnected to electrical supply for

a minimum of 1 hour or until the heater is

thoroughly dry.

Improper cleaning of the heater can cause severe

personal injury or property damage due to water and/or

cleaning solution:

1. In electrical components, connections and wires

causing electrical shock or component failure.

2. On gas control components causing corrosion which

can result in gas leaks and fire or explosion from the

leak.

Clean internal components of the heater with a soft, dry

brush or cloth, or compressed air.

1. Have your gas supplier check all gas piping annually

for leaks or restrictions in gas lines. Also, at this time

have your gas supplier clean out the sediment trap of

any debris that may have accumulated.

2. The hheater’s ssurrounding aarea sshall bbe kkept cclear aand

free ffrom ccombustible m

materials, ggasoline, aand oother

flammable vvapors aand lliquids.

3. Regulators can wear out and function improperly.

Have your gas supplier check the date codes on all

regulators installed and check delivery pressures to

the appliance to make sure that the regulator is

reliable.

4. Regulators must be periodically inspected to make

sure the regulator vents are not blocked. Debris,

insects, insect nests, snow, or ice on a regulator can

block vents and cause excess pressure at the

appliance.

5. Review all heater markings (ie. warnings, start-

up/shutdown, electrical wiring, diagrams, etc.) for

legibility. Ensure that none are cut, torn, or otherwise

damaged. Any damaged markings must be replaced

immediately by contacting L.B. White Co., Inc.

Markings are available at no cost.

1. Before cleaning, close gas supply valve to heater and

disconnect heater’s electrical supply.

2. The heater should have dir t or dust removed

periodically:

a. Af ter each flock or between building re-

population, give the heater a general cleaning

using compressed air or a soft brush on its

interior and exterior. At this time, dust off the

motor case to prevent the motor from over-heating

and shutting the heater down.

b. At least once a year, give the heater a thorough

cleaning. At this time, remove the fan and motor

assembly and brush or blow off the fan wheel,

giving attention to the individual fan blades.

Additionally, make sure the burner air inlet venturi

ports and the throat of the casting are free of

dust accumulation and the area between the heat

chamber top and inside case is also free of dust.

c. When washing with water, observe and obey the

Warning within these Cleaning Instructions. This

same Warning is also supplied on the heater.

13

Cleaning Instructions

Maintenance Instructions

WARNING

Fire, B

Burn, aand EExplosion H

Hazard

This heater contains electrical and mechanical components in the gas management, safety and airflow systems.

Such components may become inoperative or fail due to dust, dirt, wear, aging, or the corrosive atmosphere of an

animal confinement building.

Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property

damage.

Advertising
This manual is related to the following products: