Basic operation – L.B. White AW250(building controller) User Manual

Page 5

Advertising
background image

This heater uses Smart Sense

technology for variable

rate heat control. When integrated to a building controller
and L.B.White Smart Box

,

precise, automated control of

the environment is achieved by operating the heater over a
broad heat range from 65,000 btu to 250,000 btu. This
provides better, more even temperature distribution by
allowing the heater to operate where it needs to. This results
in consistent temperatures and reduced fuel consumption.

As shipped from the factory, the heater is wired to start
and operate at minimum heat. Connection to a building
environment controller capable of providing a 0-10 VDC
o r 4 - 2 0 m i l l i a m p s i g n a l f o r t h e h e a t e r ’ s Smart
Sense™gas control valve is required for further
operation.

See Fig.1 for a typical system diagram.

Sequence of Operation

a

. Call for heat occurs from building controller.

b. Building controller closes heating contacts, and

sends either 1-15 VDC or 4-20 milliamps to signal
conditioner in the heater’s control box.

c. Signal conditioner sends the signal to the

Smart

Sense

variable rate gas control valve.

-- Variable rate valve opens at specific firing rate

to meet temperature demands

d. Ignition of gas occurs.

-- Room warms to desired temperature.

e. Building controller recognizes desired temperature

has been achieved.

f. Building controller disconnects signal from heater.
h. Heater shuts down. Process begins again on a call for

heat.

5

FANS

ENVIRONMENT
CONTROLLER

CONTROL SIGNAL TO
GAS VALVE

115 VAC TO HEATER

EXISTING ROOM
SENSORS

GUARDIAN

HEATER(S) WITH

Smart Sense

FIG. 1

GUARDIAN WITH

Smart Sense

Basic Operation

Advertising