Heater specifications, Model – L.B. White AD100 User Manual

Page 5

Advertising
background image

4

Heater Specifications

Maximum Input (BTUH)

60,000

100,000

Minimum Input (BTUH)

30,000

50,000

240

400

11.0 7.0 11.0 7.0

10.0 4.0 10.0

4.0

2.78

60

4.63

100

lbs.

cu. ft.

lbs.

cu. ft.

1.39 30

2.31

50

lbs.

cu. ft.

lbs.

cu. ft.

1/15 H.P.

1/8 H.P.

1700 RPM

1100 RPM

2.0

4.0

1.1

1.6

21

1/4

x

14

1/4

x

18

29

1/2

x

14

1/4

x

18

TOP

1 ft. (.3 m)

SIDES

1 ft. (.3 m)

BACK

1 ft. (.3 m)

BLOWER

6 ft. (1.83 m)

OUTLET

GAS

Propane Gas Supply — 6 ft. (1.83 m)

SUPPLY

Natural Gas Supply — N/A

SPECIFICATIONS

AD060

AD100

Propane

Natural

Propane

Natural

Gas

Gas

Gas

Gas

Model

Ventilation Air Required
to Support Combustion (CFM)

Burner Manifold Pressure

(In.W.C.)

Electrical Supply
(Volts/Hz/Phase)

Amp Draw
(Starting Amps
Includes Igniter)

Dimensions (Inches)
L x W x H

Minimum Safe
Distances From
Nearest
Combustible
Materials

STARTING

CONTINUOUS
OPERATION

Motor Characteristics

Fuel Consumption Per
Hour

Inlet Gas Supply Pressure
Acceptable at the Inlet of the
Heater for Purpose of Input
Adjustment ( In.W.C.)

MAX.

MIN.

MAX.

MIN.

13.5

Ball Bearing

115/60/1

Heater Specifications

Advertising
This manual is related to the following products: