Optional Accessory.

Appearance of the outlet on heater may vary from model to model.

proper application of pipe compound before

further tightening.

-- Tighten the gas connection as necessary to

stop the leak.

-- If necessary, replace the parts or components

involved if the leak cannot be stopped.

-- Ensure all gas leaks have been identified and

repaired before proceeding.

12. A qualified service agency must check for proper

operating gas pressure upon installation of the heater.

13. Light according to instructions on heater or within

owner's manual.

14. It is extremely important to use the proper size and

type of gas supply line to assure proper functioning of

the heater. Contact your fuel gas supplier for proper

line sizing and installation.

15. Make sure the heater has the proper gas regulator for

the application. A regulator must be connected to the

gas supply so that gas pressure at the inlet to the gas

valve is regulated within the range specified on the

dataplate at all times. Contact your gas supplier, or

the L.B. White Co., Inc. if you have any questions.

16. This heater can be configured for use with either

propane gas vapor withdrawal or natural gas. Consult

the dataplate, located on the case panel at the burner

end of the heater, for the gas configuration of the

specific heater. Do not use the heater in a propane

gas liquid withdrawal system or application. If you are

in doubt, contact the L.B. White Co., Inc.

17. Eventually, like all electrical/mechanical devices, the

thermostat can fail. Thermostat failure may result in

either an underheating or overheating condition which

may damage critical products and/or cause animal

injury or death. Critical products and/or animals

should be protected by a separate back-up control

system that limits high and low temperatures and also

activates appropriate alarms.

18. Take time to understand how to operate and maintain

the heater by using this Owner’s Manual. Make sure

you know how to shut off the gas supply to the building

and also to the individual heater. Contact your fuel

gas supplier if you have any questions.

19. Any defects found in performing any of the service or

maintenance procedures must be eliminated and

defective parts replaced immediately. The heater

must be retested by properly qualified service

personnel before placing the heater back into use.

Alternate Air Diverter Installations

TABS

DIVERTER
HALVES

OUTLET
SCREWS

FORMED
OUTLET GUARD

NOTCHES IN MOUNTING TABS

1. Optional air diverters can be installed in the heater

outlet to provide direction to the heated air as it exits

the heater. Installation options include installing the

diverters in such a way as to broadly distribute the air

in two 45 degree paths or to focus the air flow in one

45 degree direction. See Fig. 1.

2. The air diverter’s tabs on each half will “pop” into the

blower outlet between the inside of the case assembly

and the blower housing outlet. If the notched tabs do

not “pop” into the blower outlet, loosen (do not

remove) the blower outlet screws. Doing this provides

a gap into which you can insert the tabs. Retighten

the screws after installation.

FIG. 1

(Typical installation allowing two directions of air movement.)

8

AIR DIVERTER

INSTALLATION INSTRUCTIONS