Radiant heater specifications, Model – L.B. White I-3 Infraconic User Manual
Page 5

4
Radiant Heater Specifications
SPECIFICATIONS
Model
FIG. 1
Heater Dimensions
See Fig. 1
Fuel Consumption Per Hour
Minimum Safe Clearances to
Combustible Materials
Recommended Installation Height
24 in.
2.8 CFH
10 - 12 in. W.C.
35 CFM
5 PSIG
(1)
This is a typical sensor height range for the modulating zone panel in a farrowing installations. Care should always be taken to
ensure that the sensor is sufficiently high as to not be damaged by the animal during operation.
"B"
"A"
"C"
Animal Occupied Zone Temperature
Control Sensor Location (1)
VERTICAL FROM FLOOR
18 in.
HORIZONTAL FROM CENTER OF BROODER
8 in.
I
3
Maximum Input
2,800 BTUH
Ventilation Air to Support Combustion
Zone Control
PROPANE GAS OR
Full Output Pressure
NATURAL GAS
Zone Control,
PROPANE GAS OR
Low Heat Pressure
NATURAL GAS
“A”
7-5/8 in.
“B”
7 in.
“C”
3-1/2 in.
Net Weight
3-1/2 lbs.
PROPANE GAS
.13 lbs./hr.
NATURAL GAS
24 in.above the creep mat
TOP OF SHROUD
2-1/2 ft.
VERTICALLY FROM POINT OF
COMBUSTION CONE
SIDES
2 ft.