Radiant heater specifications, Model – L.B. White I-17 Infraconic User Manual

Page 4

Advertising
background image

I

17

Maximum Input (Btuh)

17,100

Ventilation Air to Support Combustion

Zone Control

PROPANE GAS OR

Full Output Pressure

NATURAL GAS

Zone Control,

PROPANE GAS OR

Low Fire Pressure

NATURAL GAS

“A”

16-7/8 in.

“B”

10- 1/2 in.

“C”

6 -1/2 in.

Net Weight

5 lbs.12 oz.

PROPANE GAS

.80 lbs./hr.

NATURAL GAS

CHICKENS

1250 - 2000

TURKEYS

250 - 500

SWINE

170

CHICKENS

5 - 6 ft.

TURKEYS

4 ft.

SWINE

4 - 5 ft.

TOP OF HOOD TO CEILING

3 ft.

POINT OF COMBUSTION
CONE TO FLOOR

SIDES

3 ft.

4

Radiant Heater Specifications

SPECIFICATIONS

Model

FIG. 1

Heater Dimensions
(See Fig. 1)

Fuel Consumption Per Hour

Animal Coverage Per Heater (1)

Minimum Safe Clearances to
Combustible Materials

Recommended Height Installation
For Livestock From Point of
Combustion Cone to Floor

3.5 ft.

17.1 CFH

10 - 12 in. W.C.

200 CFM

5 PSIG

(1)

There are other factors that will affect the quantity of animals
each heater can cover. These include building ventilation and control systems, building insulation, building size and population
density, etc. Consult your L.B. White dealer or call L.B. White for specific recommendations for your application.

(2)

This is a typical sensor height range for poultry installations. The size and type of livestock being grown, heater spacing and height,
etc. will dictate sensor height. Care should always be taken to ensure that the sensor is sufficiently high as to not be damaged by
the animal during operation.

"B"

"A"

"C"

Animal Occupied Zone Temperature
Control Sensor Location (2)

VERTICAL FROM FLOOR

6-12 in.

HORIZONTAL FROM BROODER

8-12 ft.

VERTICAL FROM FLOOR

Above Animal Height

HORIZONTAL FROM BROODER

4-8 ft.

POULTRY

SWINE

Advertising