Installation and assembly instructions, General – L.B. White 400 Tradesman Portable Forced Air User Manual

Page 8

Advertising
background image

1.

Read all safety precautions and follow L. B. White
recommendations when installing this heater. If
during the installation or relocating of heater, you
suspect that a part is damaged or defective, call a
qualified service agency for repair or replacement.

2.

Ensure the heater is properly positioned before use.
The heater must be installed on a level, flat,and
stable surface when in operation and according to
minimum safe distances from combustible materials.
Safe distances are given on the heater dataplate and
on page 4 of this manual.

3.

This heater is approved for indoor use only. The
heater shall be installed so it is not directly exposed
to water spray, rain, and /or dripping water.

4.

The heater’s gas pressure regulator (with pressure
relief valve) must be protected from adverse weather
conditions (rain, ice, snow) as well as from building
materials (tar, concrete, plaster, etc.) which can affect
safe operation and could result in property damage or
injury.

5.

Heaters used in the vicinity of combustible tarpaulins,
canvas, plastics, wind barriers, or similar coverings
shall be located at least 10 feet from the coverings.
The coverings shall be securely fastened to prevent
ignition or upsetting of the heater due to wind action
on the covering or other material.

6.

Insure that all accessories that ship with the heater
have been and installed.

7.

Check all connections for gas leaks using approved
gas leak detectors. Gas leak testing is performed as
follows:

-- Check all pipe connections, hose connections,

fittings and adapters upstream of the gas
control with approved gas leak detectors.

-- In the event a gas leak is detected, check the

components involved for cleanliness and
proper application of pipe compound before
further tightening.

-- Tighten the gas connections as necessary to

stop the leak.

-- After all connections are checked and any

leaks are stopped, turn on the main burner.

-- Stand clear while the main burner ignites to

prevent injury caused from hidden leaks that
could cause flashback.

-- With the main burner in operation, check all

connections, hose connections, fittings and
joints as well as the gas control valve inlet and
outlet connections with approved gas leak
detectors.

-- If a leak is detected, check the components

involved for cleanliness in the thread areas
and proper application of pipe compound
before further tightening.

-- Tighten the gas connection as necessary to

stop the leak.

-- If necessary, replace the parts or components

involved if the leak cannot be stopped.

-- Ensure all gas leaks have been identified and

repaired before proceeding.

8.

A qualified service agency must check for proper
operating gas pressure upon installation of the
heater.

9.

Always use pipe thread compund that is resistant to
propane and natural gas on threaded connections.

10.

Light according to instructions on heater or within
owner's manual.

11

Make sure the heater has the proper gas regulator for
the application. A regulator must be connected to the
gas supply so that gas pressure at the inlet to the gas
valve is regulated within the range specified on the
dataplate at all times. Contact your gas supplier, or
the L.B. White Co., Inc. if you have any questions.

12. This heater is configured for use for propane gas

vapor withdrawal only. Do not use the heater in an
propane gas liquid withdrawal system or application.
If you are in doubt, contact the L.B. White Co., Inc.

WARNING

Fire and Explosion Hazard

Can cause property damage, severe injury or death

To avoid dangerous accumulation of fuel gas, turn
off gas supply at the heater service valve before
starting installation, and perform gas leak test after
completion of installation.

7

Installation and Assembly Instructions

GENERAL

WARNING

Fire and Explosion Hazard

Do not use open flame (matches, torches, candles,
etc.) in checking for gas leaks.

Use only approved leak detectors.

Failure to follow this warning can lead to fires or
explosions.

Fires or explosions can lead to property damage,
personal injury or loss of life.

Advertising