Heater specifications, Model – L.B. White 220 Plus Therma Grow User Manual

Page 5

Advertising
background image

SPECIFICATIONS

HW220

Propane

Natural

Gas

Gas

Maximum Input (BTUH)

220,000

Minimum Input (BTUH)

120,000

550 CFM

220 sq. in.

100 sq. in.

13.5

11.0

11.0

7.0

5.0

3.1

1.4

0.8

10.19 lbs.

220 cu. ft.

5.56 lbs.

120 cu. ft.

Ball Bearing

1/2 H.P.

1,100 RPM

115/60/1

230/60/1

17.1

6.7

6.2

2.6

35 x 25 x 30

TOP

1 ft.

SIDES

1 ft.

BACK

1 ft.

BLOWER
OUTLET

GAS

Propane (L.P.) Gas Supply — 6 ft. (1.83 m)

SUPPLY

Natural Gas Supply — N/A

(1) Air inlets and exhaust outlets must be electromechanically operated and electrically interlocked with the

heater to prevent heater operation if air inlet and exhaust outlet do not open when heating is required.

Model

Indoor Mounting Air
Exchange Requirements

(1)

Burner Manifold
Pressure (In. W.C.)

Electrical Supply
(Volts/Hz/Phase)

Amp Draw

Dimensions (Inches)
L x W x H

Minimum Safe
Distances From
Nearest
Combustible
Materials

STARTING

CONTINUOUS
OPERATION

Motor Characteristics

Fuel Consumption Per
Hour

Inlet Gas Supply Pressure
Acceptable at the Inlet of
the Heater for Purpose of
Input Adjustment (In. W.C.)

MAX.

MIN.

6 ft. (1.83 m)

4

Heater Specifications

Outdoor Mounting Air
Exchange Requirements

(1)

EXHAUST FAN

SHUTTERED AIR INLET

SHUTTERED
EXHAUST OUTLET

MAX.

MIN.

MAX.

MIN.

115 VOLT MOTOR

230 VOLT MOTOR

115 VOLT MOTOR

230 VOLT MOTOR

Advertising