Troubleshooting Information

PROBLEMS

CAUSES

REMEDIES

1. Pilot will not light.

* Fuel supply valves closed.

* Open fuel supply valves.

* Pilot button not fully depressed.

* Depress pilot button completely.

* Pilot orifice is plugged.

* Clean or replace pilot orifice. (DO NOT insert sharp

instruments in orifice holes, blow out with compressed

air.)

* Screen at inlet of pilot orifice is

* Remove screen and clean or replace screen.

plugged.

* Restriction in gas hose or

* Remove hose or pilot line from heater and blow

pilot line.

out with compressed air or replace if necessary.

* Air in gas line.

* Push in pilot button (normally 30 seconds is

sufficient) on pilot valve to purge air from

line (usually necessary at time of installation).

* Pilot safety gas control is defective

* Replace entire pilot safety control valve.

2. Pilot lights but will not

* Restriction in gas hose or pilot line.

* See remedy for same cause in Problem #1.

stay lit when pilot

button is released.

* Insufficient time allowed for pilot

* Hold in pilot button for 30 seconds to allow proper

light to heat up thermocouple.

warm up.

* Loose thermocouple.

* Tighten thermocouple at gas control and at pilot bracket.

* Defective thermocouple.

* Replace thermocouple.

* Pilot orifice is plugged.

* See remedy for same in Problem #1.

* Defective pilot safety control valve.

* Replace entire pilot safety control valve.

* Improper gas pressure.

* Set pressure according to pressure on dataplate.

3. Main burner will not

* Main burner valve closed on heater.

* Open all valves.

light.

* Pilot light not lit.

* Light the pilot.

* Burner orifice plugged.

* Clean the burner orifice.

4. Burner flame lifting

* Fuel pressure set too high.

* Set pressure according to pressure on dataplate.

off burner.

* Blockages in burner orifice or at

* Clean suspected area with soft brush, dry cloth,

primary air inlets of burner.

or compressed air.

5. Heater does not seem

* Gas supply valves not fully open.

* Open valves completely.

to be delivering

maximum heat output.

* Burner orifice plugged.

* Clean burner orifice with compressed air or replace.

* Low fuel supply pressure.

* Consult propane gas supplier. Cylinder or tank needs

replacement or refill. Regulator needs adjustment.

Check for use of proper regulation and fuel gas.