BURNER MOUNTING
BRACKET

JAM NUT TIGHTENED
AGAINST BURNER
MOUNTING BRACKET

THERMOCOUPLE TO SAFETY
CONTROL VALVE

PILOT TUBE TO 90

o

ELL

TIP OF BURNER ORIFICE
IS FLUSH WITH INSIDE
OF BURNER

JAM NUT

BURNER MOUNTING
BRACKET

MOUNTING HOLE
IN BURNER

TAB

6. Thread jam nut onto burner orifice so it butts up

against hex at end of orifice threads. See Fig. 6

FIG. 6

7. Position the burner casting within the burner

mounting bracket. The tab on the burner bracket
must fit within the mounting hole of the burner
casting. See Fig. 7.

FIG. 7

8. Thread the orifice with control assembly into the inlet

of the burner casting so that the tip of the burner
orifice is flush with the inside of the burner and so
the control assembly is positioned as shown. See
Fig. 8.

FIG. 8

9. Tighten the jam nut up against the burner mounting

bracket. See Fig. 9.

FIG. 9

10. Carefully hand form the thermocouple and pilot line

through the hole in the burner mounting bracket to
align with safety control valve. See Fig. 10.

11. Thread the thermocouple connector nut into the pilot

safety control valve. Tighten finger tight and snug
into place with the appropriate wrench. See Fig. 10.

12. Slide the remaining compression nut and sleeve onto

the other end of the pilot line tube. Thread the
compression nut onto the 90 degree elbow at the
safety control valve while firmly pushing the pilot tube
into the elbow. Tighten the compression nut securely.
See Fig. 10.

FIG. 10

9

9

JAM NUT

HEX ON
BURNER ORIFICE

Advertising