Pilot orifice, instaclear, Standard, Instaclear – L.B. White I-34 Infraconic Pilot Ignition User Manual
Page 15: Standard pilot fig. 13, Fig. 12, Pilot

The instructions apply to both pilot designs.
1. Loosen injector tube screw.
2. Loosen pilot tube compression nut at gas inlet to pilot
assembly.
3. Remove thermocouple from pilot safety control valve.
4. Slightly pull control assembly with pilot tube away
from injector body.
5. Loosen orifice holder.
6. Remove pilot orifice from its holder.
7. Clean orifice.
■
Use care when servicing InstaClear™ orifice to avoid
damage to clean-out pin.
PILOT ORIFICE, INSTACLEAR
™