Instructions for replacing BMI pump-canister with BMII pump canisters by

re-using existing shaft & fixing screws


Step 1
Remove the BMI pump canister assembly from the Turntable by removing the two or three
canister hold down screws. Retain these screws for use in the new assembly.

Step 2
Remove the split pin from the newly received BMII canister assembly.


Step 3:
Once the split pin is removed, the plastic or metal stirrer shaft will come out easily.


Replace the new ‘L-neck’ Crank shaft with the existing ‘S’ or ‘Flat end Paddle’ type crank
shaft using the supplied Split Pin.