Disassembly Procedure for GFB BOVs (part #’s 1001 to 1005)

This procedure is used for changing the base adaptor or spring on the universal blow-off valve range

1001-1005, and general disassembly for inspection, repair or maintenance.

1.

Using a 1.5mm hex key, begin by removing

the small grub screw on the side of the body

marked 1.

2.

Now unscrew the base (2), taking care as the

spring will push the valve apart as you near the end

of the thread. It is a good idea to do this step over a

rag or cloth to catch any parts that may drop.

3.

Replace the new base or spring with the

internal parts in the correct order as shown in the

exploded view. It is easiest to rest the base on a

table, then stack the parts on top, and lower the

body down onto the base. Press down to compress

the spring and screw the body onto the base.

4.

Tighten the base as much as possible by hand,

then replace the grub screw (1).

5.

Change the plumb back adaptor (3) by simply

unscrewing it. No additional fasteners are used

here.

6.

Standard fittings supplied are 5035, which is

a 35mm base, which can also be mounted onto 1”

hard pipe. The standard plumb back adaptor is

5230, which is 30mm.

GFB technical support:

Ph: +612 9534 0099

Email:

[email protected]