Maintenance, Maintenance schedule, Fluid levels – MBW GP18 User Manual
Page 9: Engine maintenance, Engine speed, Aintenance
- 6 -
M
AINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1.
Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
Fluid Levels
1.
MBW #01058---- 6-Pack (8 oz bottles)
MBW #17320---- 1 quart (32 oz)
Engine Maintenance
Refer to the engine owner’s manual for maintenance
intervals and procedures.
Engine Speed
1.
The engine speed is factory set according to the
specifications section of this manual. Do not tamper
with the governor setting. The governor establishes
safe operating limits which must not be exceeded.
SYSTEM
MAINTENANCE
EACH USE
EVERY 50
HOURS
EVERY 250
HOURS
YEARLY
Engine
Refer to engine operator/owner manual
X
Exciter
Check for oil leaks
X
Change oil
X
X
Tighten Bolts
1
X
X
Hardware
Check and tighten as needed
1
X
X
Shockmounts
Check for cracks or tears
X
X
SYSTEM
FLUID VOLUME
RECOMMENDED OIL
Exciter
2 oz (GP12 &12)
1.5 oz (GP18)
MBW Ground Pounder
®
Exciter Oil
1
Engine
Refer to engine operator/owner manual