Ervice, Torque chart service tools replacing shockmounts, Replacing input seal – MBW AT84 User Manual

Page 10: Removing drive coupler

Advertising
background image

- 7 -

S

ERVICE

Assembly and disassembly should be performed by a
service technician who has been factory trained on MBW
equipment. The unit should be clean and free of debris.
Pressure washing before disassembly is recommended.

• Prior to assembly, wash all parts in a suitable cleaner or

solvent.

• Check moving parts for wear and failure. Refer to the

Replacement section in this manual for tolerance and
replacement cycles.

• All shafts and housings should be oiled prior to pressing

bearings. Also, ensure that the bearings are pressed
square and are seated properly.

• All bearings should be replaced when rebuilding any

exciter or gearbox.

• All gaskets and seals should be replaced after any

disassembly.

Torque Chart

Service Tools

Replacing Shockmounts

1.

Support roller to prevent it from rolling, and remove
hydraulic hoses from motor.

2.

Remove the two bolts securing the hydraulic motor
and remove the motor.

3.

Remove all external shockmount hardware while
supporting frame. Lift frame assembly off of drum
assembly.

4.

Pull spider off of drum.

5.

Replace shockmounts as needed.

6.

While spider is removed, inspect coupling and seal
for excessive wear. Replace if needed.

7.

Reinstall spider onto drum and then into the frame

8.

Install motor, align with coupler and secure with
mounting screw and lock washer. Use a medium
strength thread locker. Make sure motor mount
surface bottoms out in frame.

9.

Connect hoses.

Replacing Input Seal

Refer to Main Assembly, page 14.

1.

Remove drum assembly from frame and spider from
drum (See “replacing shockmounts” steps 1-4)

2.

Using a seal puller, remove seal. Note it is not
necessary to remove gear coupler (#15)

3.

Inspect the sealing surface on the shaft for wear or
damage.

4.

If the shaft has any sign of wear or damage, remove
the gear coupler (#15) and use the sleeve included
with seal. (Follow instructions included with seal kit).
If the shaft is in good condition install only the seal.
Use a seal protector when installing the seal.

Removing Drive Coupler

Refer to Main Assembly, page 14.

1.

Remove hydraulic lines from motor.

2.

Remove hydraulic motor (# 6).

3.

Remove drive coupler (# 13) gear from motor by
loosening clamping screw.

SIZE

GRADE 2

GRADE 5

GRADE 8

1/4-20

49 in

lbs

76 in

lbs

9 ft

lbs

1/4-28

56 in

lbs

87 in

lbs

10 ft

lbs

5/16-18

8 ft

lbs

13 ft

lbs

18 ft

lbs

5/16-24

9 ft

lbs

14 ft

lbs

20 ft

lbs

3/8-16

15 ft

lbs

23 ft

lbs

33 ft

lbs

3/8-24

17 ft

lbs

26 ft

lbs

37 ft

lbs

7/16-14

24 ft

lbs

37 ft

lbs

52 ft

lbs

7/16-20

27 ft

lbs

41 ft

lbs

58 ft

lbs

1/2-13

37 ft

lbs

57 ft

lbs

80 ft

lbs

1/2-20

41 ft

lbs

64 ft

lbs

90 ft

lbs

9/16-12

53 ft

lbs

82 ft

lbs

115 ft

lbs

5/8-11

73 ft

lbs

112 ft

lbs

159 ft

lbs

5/8-18

83 ft

lbs

112 ft

lbs

180 ft

lbs

3/4-16

144 ft

lbs

200 ft

lbs

315 ft

lbs

1-8

188 ft

lbs

483 ft

lbs

682 ft

lbs

1-14

210 ft

lbs

541 ft

lbs

764 ft

lbs

1-1/2-6

652 ft

lbs

1462 ft

lbs

2371 ft

lbs

M 6

3 ft

lbs

4 ft

lbs

7 ft

lbs

M 8

6 ft

lbs

10 ft

lbs

18 ft

lbs

M 10

10 ft

lbs

20 ft

lbs

30 ft

lbs

CONVERSIONS

in

lbs x 0.083 = ft

lbs

ft

lbs x 12 = in

lbs

ft

lbs x 0.1383 = kg

m

ft

lbs x 1.3558 = N

m

Part #

Description

07353

CLUTCH REMOVAL TOOL

Advertising
This manual is related to the following products: