Aintenance – MBW AR57 User Manual

Page 9

Advertising
background image

- 6 -

M

AINTENANCE

WARNING

Always exercise the stopping procedure before
servicing or lubricating the unit.

After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.

CAUTION

Always verify fluid levels and check for leaks after
changing fluids.

Do not drain oil onto ground, into open streams,
or down sewage drains.

Maintenance Schedule

1.

Change oil in lower unit after first 50 hours of operation, then follow the maintenance schedule.

2.

Check all hardware after the first 5 hours of use, then follow the maintenance schedule.

Fluid Levels

Checking Percussion System Oil

Refer to Lower Unit Assembly, page 16.

The rammer percussion system and gearbox are lubricated
by an oil mist which is formed and carried throughout the
rammer by a pumping action in the machine's lower system.

1.

Before daily operation, place the rammer on a flat
surface and check the oil level in the glass sight (#12)
on the spring box (#14).

2.

If the oil is not visible in the sight gauge, add oil as
required. See Fluid Levels above for recommended
type of oil.

Changing Percussion System Oil

Refer to Lower Unit Assembly, page 16.

1.

Tip the rammer backward so the handle is on the
ground.

2.

Remove the pipe plug (#19) below the sight glass
(#12) on the back of the spring box (#14).

3.

Place an oil pan under the drain hole.

4.

Rotate the rammer to drain the oil into the oil pan.
The gearbox may need to be elevated to get all of the
oil to drain.

5.

Replace the pipe plug.

6.

Lay rammer with valve side down.

7.

Remove the pipe plug (#33, page 14) next to the
breather on the top of the gearbox.

8.

Fill the system with oil. See Fluid Levels above for
recommended type and quantity of oil.

9.

Replace pipe plug in gearbox.

SYSTEM

MAINTENANCE

EACH USE

EVERY 25

HOURS

EVERY 300

HOURS

YEARLY

Percussion
System

Check oil level

X

X

Change oil

1

X

X

Hardware

Check and tighten as needed

2

X

X

Shockmounts

Check for cracks or tears

X

SYSTEM

FLUID VOLUME

RECOMMENDED OIL

Percussion System

12 oz (360 ml)

Service SF SAE 10W-30

Advertising
This manual is related to the following products: