The power cord should only be

replaced by a qualified person. Use a

4Ćwire power supply cord (see

electrical connection U.S.A. below).

For U.S.A.

Your dryer comes without a power

supply cord.

The power cord must

meet the following requirements:

-

UL listed in the USA

-

208 ć 240 volt rated (minimum)

-

30 amps

-

Type SRDT or DRT (UL 2158)

-

Five feet long (minimum)

d

WARNING

d

Power cord must be connected

by a licensed electrician only.

Use only a U.L. approved

30 amp power cord with strain

relief clamp -

note manufacturer's instructions.

Do not plug end of power cord

into a live receptacle before

connecting power cord to

appliance terminals and closing

junction/splitter box as described

below.

Do not reuse old power cord.

Cord must have closed loop or

upturned end wire terminating

connectors.

Do not make a sharp bend or crimp

wiring/conductor at connections.

Only a 4Ćconductor cord shall

be used when the appliance is

installed in a mobile home, in a

recreational vehicle, in a new branch

circuit installation or an area where

the local codes do not permit

grounding through the neutral.

Connecting 4Ćwire power supply

cord

1. Remove the screws from the cover

of the terminal block located at the

top rear of the appliance.

1

2

3

1 - terminal block
2 - grounding strap
3 - Angle bracket for strain relief clamp

2. Loosen the bottom screw of the

grounding strap. Place the screw

to the GROUND location.

Straighten the grounding strap and

hang loosely.

3. Fix the strain relief clamp to the

angle bracket. Tighten the nut.

4. Loosen the 2 screws labeled L and

the screw labeled N in the terminal

block. and the screw of the

GROUND terminal.

5. Thread the 4 wire cable through the

U.L. strain relief clamp.

6. Tighten the screws (2.5 Nm) of the

U.L. strain relief clamp so that the

power cord cannot be moved.

7. Attach the power cord ground

conductor (green) to the GROUND

terminal. Tighten the screw (2.5

Nm) so that the ground conductor

is held securely in place.

8. Attach the 2 power cord outer

conductors (red and black) to the 2

terminals labeled L and the

remaining power cord conductor

(white) to the terminal labeled N.

9. Tighten all 3 screws (3 Nm) so that

the power conductors are held

securely in place .

10. Check the U.L. strain relief clamp

to make sure that it is tight and

cannot be turned.

11. Replace the cover on the terminal

block and fasten in place.

i

Make sure that the U.L. strain relief

clamp is outside the cover!

The appliance is now ready to be

plugged into the 4Ćwire receptacle of

the power rating.

Connecting 3Ćwire power supply

cord

1. Remove the screws from the cover

of the terminal block located at the

top rear of the appliance.

2. Make sure that there is

a grounding strap.

3. Fix the strain relief clamp to the

angle bracket. Tighten the nut.

4. Loosen the 2 screws labeled L and

the screw labeled N in the terminal

block.

5. Thread the 3Ćwire cable through

the U.L. strain relief clamp.

6. Tighten the screws (2.5 Nm) on the

U.L. strain relief clamp so that the

power cord cannot be moved.

7. Attach the 2 power cord outer

conductors (red and black) to the 2

terminals labeled L and the

remaining power cord conductor

(white) to the terminal labeled N.

8. Tighten all 3 screws (3 Nm) so that

the power conductors are held in

place securely.

9. Check the U.L. strain relief clamp

to make sure that it is tight and

cannot be turned.

10. Replace the cover on the terminal

block and fasten in place.

i

Make sure that the U.L. strain relief

clamp is outside the cover!

Additional grounding procedure

-

Some local regulations may

require a separate ground. In such

cases, the required accessory

ground wire, clamp and screw

must be purchased separately.

-

Never ground the dryer to plastic

plumbing lines, gas lines or water

pipes.