Bunn Dual SH User Manual

Page 36

Advertising
background image

Page 36

29877 090401

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

•

Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.

•

All electronic components have 120 - 240 volt ac and low voltage dc potential on their terminals.
Shorting of terminals or the application of external voltages may result in board failure.

•

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be
permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or
a loose connection at a terminal or crimp.

•

Solenoid removal requires interrupting the water supply to the valve. Damage may result if
solenoids are energized for more than ten minutes without a supply of water.

•

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened.
This will help avoid twists and kinks in the tubing.

•

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

•

This brewer is heated at all times. Keep away from combustibles.

WARNING

•

Exercise extreme caution when servicing electrical equipment.

•

Disconnect the brewer from the power source when servicing, except when electrical tests are
specified.

•

Follow recommended service procedures.

•

Replace all protective shields or safety notices.

Screen Displayed

Possible Cause

Troubleshooting Procedures

1. Overflow cup is full of water.

1. Soft Heat

®

Server not correctly

positioned on base.

2. Not using a Soft Heat Server, and
the SERVER LOCKOUT function is
activated (on).

Empty cup

Position the server so that the con-
nector pins on the server make con-
tact with connector on the brewer.

Disable the SERVER LOCKOUT func-
tion. See page 32 for procedure.

Advertising