Page 8

MX15/19

B

ATTERY

M

AINTENANCE

• Check the battery fluid level daily, especially if the work platform is being used in a warm, dry

climate.

• If electrolyte level is lower than 3/8 in. (10 mm) above the plates add distilled water only. DO

NOT use tap water with high mineral content, as it will shorten battery life.

• Keep the terminals and tops of the batteries clean.
• Refer to the Service Manual to extend battery life and for complete service instructions.

B

ATTERY

C

HARGING

Figure 8: Battery Charger

Charge the batteries at the end of each
work shift or sooner if the batteries
have been discharged.

1. Check the battery fluid level. If the battery fluid level is lower than 3/8 in. (10 mm) above the

plates add distilled water only.

2. Connect an extension cord to charger outlet plug in Left Module Door. Plug the extension cord

(12 guage (1.5 mm

2

) minimum conductor diameter and 50 ft. (15 m) maximum length) into a

properly grounded outlet of proper voltage and frequency.

3. The charger turns on automatically after a short delay. The LED charge indicator will illumi-

nate. After completion of the charge cycle the LED will blink, indicating that the charger is in a
continuing maintenance mode. DO NOT leave the charger plugged in for more than 48 hours,
as permanent damage to the batteries may occur.

NOTE: The battery charger circuit must be used with a GFI (Ground Fault Interrupt) outlet.
DO NOT operate the machine while the charger is plugged in.

W A R N I N G

!

!

Hazard of explosive gas mixture. Keep sparks, flame, and smoking material
away from batteries.
Always wear safety glasses when working near batteries.
Battery fluid is highly corrosive. Thoroughly rinse away any spilled fluid with
clean water.
Always replace batteries with UpRight batteries or manufacturer approved
replacements weighing 62 lbs. (28 kg) each.

Charger Outlet
Plug

LED Indicator

W A R N I N G

!

!

Charge the batteries in a well ventilated area.
Do not charge the batteries when the work platform is near a source of
sparks or flames.
Permanent damage to the batteries will result if the batteries are not
immediately recharged after discharging.
Never leave the battery charger operating for more than two days.
Never disconnect the cables from the batteries when the charger is operating.
Keep the charger dry.