Maintenance, Routine service – Snorkel SL20-sn5800-9299 User Manual
Page 6

6
Maintenance
Never perform service on the work plat-
form while the platform is elevated.
Note: No normal (routine) maintenance on the
SL20 should require the platform to be raised.
ROUTINE SERVICE
Use the following table as a guide for routine
maintenance, refer to the Service Manual for
complete service instructions.
SERVICE OPERATION
INTERVAL
Monthly6 Months Yearly 2 Years
Daily Weekly
or
or
or
or
50 Hrs. 250 Hrs. 500 Hrs.1000 Hrs.
Clean entire work platform
X
Check battery fluid level
X
Charge batteries
X
Check tyres for damage
X
Check lug nuts/bolts
X
Check hydraulic fluid level
X
Check for peeling, faded or
X
missing labels & replace
Check deck and guardrail
X
fasteners for proper torque
Inspect elevating assembly
X
for bends or cracking
Check for & repair collision
X
damage
Check emergency lowering
X
valve operation
Lubricate entire work
X
platform
Check electric motor
X
brushes
Check pivot pin snap rings
X
Change hydraulic filter
X
and clean breather
Check all fasteners for
X
proper torque
Grease wheel bearings
X
Change hydraulic fluid
X