Snorkel SPM20 CE-sn0001+ User Manual
Page 35

32
DRIVE Disabled
LIFT DOWN Disabled
Drive Speed Cup-Back (Turtle) Mode
Engaged (When Platform is Elevated)
LIFT UP Disabled
Both LIFT UP and LIFT DOWN Disabled
Battery Charger (AC) Plugged In
- +
LCD Display Fault Conditions
Table 3-3, LCD Display – Operating Fault Conditions show common LCD display Fault
indications which may occur during operation and are usually caused by either an error in
machine operation or a work area condition. These fault conditions can usually be corrected
by the operator and do not require a qualified mechanic to repair.
IMPORTANT
AFTER A FAULT CONDITION IS CORRECTED THE MACHINE POWER MAY NEED TO
BE RECYCLED TO RESET THE GROUND CONTROL STATION.
Table 3-3. LCD Display – Operating Fault Conditions
FAULT
CODE
PLATFORM
CONSOLE
LED FAULT
CODE
LCD SYMBOL SCREEN
LCD TEXT
SCREEN
FAULT
DESCRIPTION/
MACHINE
CONDITION
LOOK FOR THIS
_
_
Brakes Released
(DRIVE
Disabled)
To Engage
Brakes-Press
Brake Release
Button on Ground
Control Station
BRAKES RELEASED
+
-
00000.0