15
Hydraulic Fluid Level Dipstick
The dipstick on the reservoir fill cap indicates the proper
level of hydraulic fluid in the reservoir. The reservoir is
inside the front of the chassis (refer to Figure 5.3).
Figure 5.3 – Inside Front of Chassis
Remove the chassis cover and check the fluid level with
the aerial platform in the stowed position. Otherwise, the
cylinders act as a large reservoir for hydraulic fluid mak-
ing the level appear too low. The fluid should be visible
on the dipstick.
Chapter 5 – Gauges and Displays
The aerial platform is equipped with an hour meter and
a battery charge indicator to monitor the condition of the
machine before and during operation.
Diagnostic Center Display
The diagnostic center LCD display (refer to Figure 5.1) is
located on the right side of the lower control panel.
Figure 5.1 – Diagnostic Center LCD Display
When the battery disconnect is plugged in and the emer-
gency stop button is enabled at the lower controls, the
LCD display shows:
• The accumulated aerial platform operating time
• The available battery power to operate the machine.
Battery Charge Indicator
The battery charge indicator is on the battery charger on
the right side of the chassis (refer to Figure 5.2). When
the batteries are charging, the battery charge indicator
displays the level of charge in the batteries.
Figure 5.2 – Right Side of Chassis
Battery Charge
Indicator
Fill Cap