Chapter 7. Pre-operational Inspection

At the start of each work day (or 8 hour shift), an
EPV16J qual i fied op er a tor must per form the
Pre-op er a tional In spec tion as listed in the ta ble be -
low.

The pur pose of the Pre-op er a tional In spec tion is to
keep the EPV16J in proper work ing con di tion and
to de tect signs of mal func tion at the ear li est pos si -
ble time.

The EPV16J should be in the STOWED POSITION
and the Mas ter Key Switch set to OFF be fore you
be gin this in spec tion.

De fec tive parts and/or equip ment mal func tions
jeop ar dize the safety of the op er a tor and other per -
son nel, and can cause dam age to the ma chine.

DO NOT operate an EPV16J that is known to
be damaged or malfunctioning.

R e p a i r a l l e q u i p m e n t d a m a g e o r
malfunctions, before placing the EPV16J
into service.

EPV16J – 11089A

page 7 - 1

Item

Service Required

Engine fuel level

Look to see that the fuel tank is full

Fuel tank cap

Check to see that the cap is tight

Engine oil level

Check oil level (between dipstick lines)

Fuel leaks

Visually inspect (hoses and connections)

Engine coolant

Check that grills are not blocked

Wiring harnesses

Visually inspect (installation, condition)

Battery terminals

Visually inspect (no corrosion)

Battery fluid level

Check fluid level (1/4" or 6 mm below filler neck)

Hydraulic oil level

Visually inspect level (between lines on gauge)

Hydraulic oil leaks

Visually inspect (hoses, tubes)

Bolts and fasteners

Visually inspect (condition)

Structural damage and welds

Visually inspect (weld cracks, dents)

Lanyard anchor points

Visually inspect (condition)

Platform gravity gate

Check condition and operation

Platform guardrails

Visually inspect (condition)

Flashing light (option)

Visually inspect (operation)

Ground control switches

Actuate and inspect for proper operation

Emergency lower

Check operation (causes correct motion)

Platform control box switches

Actuate and inspect for proper operation

RCD/ELCB AC outlet (option)

Check operation

Platform work lights (option)

Check operation

Placards and decals

Visually inspect (installation, condition)

Pre-operational Inspection Table