9. Emergency Operation

■ Emergency Operation Procedures

The fol low ing pro ce dures are emer gency pro ce -
dures only. DO NOT use them for nor mal op er a -
tion. Their pur

pose is to get the plat

form and

op er a tor safely to ground when the MHP16/47 will
not start or some other prob lem keeps the plat form
from low er ing in the nor mal way.

❑

Operation From Platform Control Box

Switch set tings listed in the three steps be low must
ex ist at the ground be fore emer gency op er a tion
pro ce dures will work at the plat form con trol box:

Figure 9.1 - Lower Control Box

1. The Master Key Switch  must be ON (see

Figure 9.1).

2. The Emergency Stop switch € must be

(ON) (see Figure 9.1).

3. The Platform/Ground Selector switch 

(see Figure 9.1) must be set to PLATFORM.

Figure 9.2 - Upper Control Box

4. Set the Emergency Stop switch ‚ to ON

(see Figure 9.2).

5. Set the Anti-Restart switch ƒ (see Figure

9.2) to ON.

Figure 9.3

6. Step on the platform foot switch „ (see

Figure 9.3).

Figure 9.4

7. Hold the Emergency Lower switch … (see

Figure 9.4) down and the platform will begin
lowering.

NOTE:

To slew when using emergency lowering operate
the slew switch
† in the direction required.