Air line 7-9, All motion alarm 7-9, Driving and work lights 7-9 – Snorkel SP22 User Manual
Page 43: Platform control cover 7-9, Chapter 7. pre-operational inspection

be sure you disconnect it before you drive the SP
away.
Figure 6.19—RCD / ELCB
■ Air Line
If the machine is equipped with the optional air line,
connect an air line of 250 psi (1,724 kPa) to the
input connector. The input connector is at the lower
rear of the turntable.
Connect an air tool to the air outlet at the platform
and try to operate the tool to verify that the air line is
free of kinks or holes that may prevent air flow.
■ All Motion Alarm
The machine is equipped with an all motion alarm.
Drive in both the forward and reverse directions to
ensure that the alarm sounds to warn personnel in
the area that the aerial platform is in motion.
■ Driving and Work Lights
The machine may be equipped with driving lights
and/or platform working lights. Turn the engine on
and use the switch on the back of each light to
momentarily turn it on to see that it works.
■ Platform Control Cover
The machine may be equipped with an optional
platform control cover. Inspect the cover to ensure
it fits properly over the control panel.
SP20/SP22 – 11890A
page 7 - 9
Chapter 7. Pre-operational Inspection
RCD
Power Input
Connector
Power Outlet
At Platform