Chapter 5 – Gauges and Displays
18
TB42J – 0172310
Fluid Level and Temperature Gauge
A gauge on the right end of the reservoir displays the
level and temperature of the hydraulic fluid (refer to Fig-
ure 5.5).
Figure 5.5 – Hydraulic Fluid Gauge
If the temperature rises above 200°F (93°C) stop machine
operation and let the fluid cool before resuming opera-
tion.
Hydraulic Fluid Filter Gauge
The fluid filter gauge (refer to Figure 5.4) is located on the
return line filter on top the reservoir. The reservoir is be-
hind the door on the left side of the turntable. During high
pump flow situations, the gauge indicates the condition
of the filter. When the needle on the gauge is in the red
zone, it is time to change the filter.
Figure 5.4 – Hydraulic Fluid Filter Gauge
Filter Gauge
Fluid Level and
Temperature Gauge