Powergas – Bock Water heaters Turboflue 71PG-361PG User Manual

Page 2

Advertising
background image

PowerGas

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80014-C Rev 5/08

*Nipple not included

**Optional setting, contact factory

***Weight does not include burner and controls

T&P Valve: Factory Installed

Drain Valve: Factory Installed Brass Valve

Standard Voltage (all): 120V, 60 Hz, 1P

Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi

ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards.

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local

codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Bock recommends a tempering valve or

anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

(on selected models)

541PG

72PG, 73PG, 120PG,

71PG

190PG, 241PG, 361PG

Model Storage

(gal)

Rated

Input

Recovery

@ ∆ 90°F

(GPH)

Max. Temp

Setting

(°F)

Inlet

Pipe

Dia.

Outlet

Pipe

Dia.

Return

Pipe

Dia.

Dimensions

Shipping Weight

(lbs)***

BTUH

A

B

C

D

E

Standard

ASME

71PG

68

173,000

170

160**

1”

1 1/2”*

1 1/2”

66”

26”

6”

13 1/2”

22”

478

N/A

72PG

67

199,000

204

160**

1”

1 1/2”*

1 1/2”

58”

28”

8”

16”

N/A

543

N/A

73PG

67

242,000

247

180

1”

1 1/2”*

1 1/2”

58”

28”

8”

16”

N/A

548

N/A

120PG

113

155,000

160

180

1”

2”*

2”

67”

31 1/2”

6”

19”

22”

749

N/A

190PG

113

190,000

191

180

1”

2”*

2”

67”

31 1/2”

6”

19”

22”

749

N/A

241PG

109

277,000

283

180

1”

2”*

2”*

67”

31 1/2”

8”

19”

22”

901

943

361PG

91

385,000

435

180

1”

2”*

2”*

67”

31 1/2”

9”

23”

26”

1,080

1,116

541PG

83

623,000

627

180

2”

2”*

2”*

66”

34”

10”

22”

30 1/2”

1,313

1,569

No field conversion kits available.

Maximum inlet gas pressure for natural gas: 10” w.c.; propane: 13” w.c. Minimum inlet gas pressure for natural gas: 4.5” w.c.; propane: 11” w.c.

Burner protrudes 12” - 14” from tank depending on make and model. Contact Bock for burner detail dimensions.

This product is available from:

Outlet

Auxiliary

Outlet:

71PG-EC

Inlet

T&P

Relief

Valve

D

C

B

E

A

Aquastat

Connection

Drain

Valve/

Return

Hand-Hole

Outlet

Auxiliary

Outlet

Inlet

T&P

Relief

Valve

D

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Hand-Hole

Return:

120PG,

190PG,

241PG,

361PG

Outlet

High Limit

Inlet/

Return

T&P

Relief

Valve

C

B

E

A

Drain

Valve

Aquastat

Connection

Hand-Hole

Advertising