SECTION 2 - PROCEDURES

2-32

– JLG Sizzor –

3121103

2.27 LIMIT SWITCH ADJUSTMENT

PROCEDURE

Drive Cut-Out Switch

NOTE: The drive cut-out switch is set at 22 ft (6.7 m).

Drive Speed Cutout

Drive speed limit switch set to actuate as soon as possible
after the platform lifts beyond the stowed position and
begins to elevate. Switch must activate prior to a maxi-
mum platform height of 14 ft (4.2 m).

Figure 2-14. Drive Hub Engaged

Figure 2-15. Drive Hub Disengaged

Figure 2-16. Drive Cut-out Switch

Figure 2-17. Drive Speed Cutout Switch