SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROLS

3-9

– JLG Lift –

3120742

3.

Rotate. (35/n35/40/n40/45 electric)

A three position ROTATE control switch permits rotation of
the platform when positioned to left or right.

4.

Platform Leveling Override.
(35/n35/40/n40/45 electric)

A three position LEVEL control switch allows the operator
to compensate for any difference in the automatic self lev-
eling system by positioning the control switch to UP or
DOWN.

5.

Lower Boom Lift.

Provides for raising and lowering of Lower Boom and
(Mid Boom on 40/n40/45 electric) when positioned to UP
or DOWN.

6.

Upper Boom Lift.

Provides for raising and lowering of Upper Boom when
positioned to UP or DOWN.

7.

Telescope. (35/n35/40/n40/45 electric)

Provides for extension and retraction of Upper Boom
when positioned to IN or OUT.

8.

Swing.

The SWING control switch provides 360 degrees non-con-
tinuous turntable rotation. To activate SWING, position
switch to LEFT or RIGHT.

9.

Circuit Breakers.
(March 1995 to Present)

The circuit breakers open (pop out) to indicate a short or
overload somewhere on the machine.

10.

Battery Indicator and Hourmeter .

An hourmeter, installed in the upper portion of the Ground
Control Box, registers the amount of machine operating
time. The hourmeter registers up to 9,999.9 hours and
cannot be reset.

Figure 3-3. Ground Control Station, 30 electric. (Sheet 1 0f 4)