Display, Display -3 – JLG 4009 Suspended Load Supplement Operator Manual User Manual

Page 25

Advertising
background image

Section 2 - Load Management Indicator System (LMIS)

2-3

31200487

Display

1. Attachment - Current attachment selection (see page 2-5).

a. OFF - Select when lifting a non-suspended load. Minimal information shown

on display. Capacity charts located in the operator cab must be used.

b. Truss Boom attachment selected.

2. Operating Mode

c. Outriggers fully engaged.

d. Outriggers not engaged.

3. Boom Length - Displays boom length in meters or feet.

4. Bargraph - Displays approximate percentage of rated capacity.

5. Boom Height - Displays boom height in meters or feet.

6. Load Percentage - Displays approximate load percentage of the rated capacity.

7. Load - Displays approximate load in metric ton or k-pounds. Load includes

object being lifted and all rigging (slings, etc).

8. Boom Angle - Displays boom angle in degrees.

9. Rated Capacity - Displays rated capacity in metric ton or k-pounds.

10. Reach - Displays boom reach from front of tires in meters or feet.

11. Message Display Window - Displays general system information, alarms and

warnings.

Note: To change display brightness, depress ESC for 2-3 seconds. As the display
cycles through various levels of brightness, depress ENT when the desired
brightness is reached.

OZ3410

0.0

0.0

0.0

m

0.0

m

0.0

d

0.0

m

0

XXXXX
XXXXX

t

t

max

1

3

4

5

6

7

8

9

10

11

a

b

c

d

2

OFF

Advertising