Section 2 - Load Management Indicator System (LMIS)

2-6

31200487

Lifting Conditions and Alarms

The control panel and external audible beacon tower (if equipped) display machine
operating conditions.

1. Green Light - Illuminates when load is less than rated capacity.

2. Yellow Light - Illuminates and intermittent alarm sounds when load is

approaching rated capacity.

3. Red Light - Illuminates and constant alarm sounds when automatic function

cut-out is activated. Certain functions are disabled (i.e. boom lift, extend, etc).
Retract boom to re-enable functions.

4. Bargraph - See page 2-3.

5. Automatic Function Cut-Out Override (not illustrated) - Momentarily disables the

automatic function cut-out. Indicator flashes while activated.
Switch/button and indicator locations vary by model. Refer to the machine
Operation & Safety Manual for location details.

Note: Override will only function for 30 seconds. After 30 seconds, boom functions
will cease and the switch/button will need released and depressed again.

WARNING

TIP OVER HAZARD. Exceeding lift capacity of the telehandler could damage the
equipment and/or cause tip over resulting in death or serious injury.