JLG 3246ES Service Manual User Manual

Page 139

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

3121166

– JLG Lift –

5-19

8 2

LSS CELL #2 ERROR

Cell #2’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #2’s Internal Memory.
8-2 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 2 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.

This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.

8 3

LSS CELL #3 ERROR

Cell #3’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #3’s Internal Memory.
8-3 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 3 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.

This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.

8 4

LSS CELL #4 ERROR

Cell #4’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #4’s Internal Memory.
8-4 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 4 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.

This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.

Help messages with the 9-x flash codes indicate controller (module) problems. The second digit of the flash code provides additional information

about the difficulty.

9 1

LSS WATCHDOG RESET

The Watchdog Timer on Load Sensing System Module’s micro-
processor was triggered by exposure to excessive electrical
noise, or by a hardware difficulty.
9-1 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“WATCHDOG RST” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL]. Retained until power is re-
cycled.
No motion interlocks.

Re-cycle power to clear diffi-
culty

9 2

LSS EEPROM ERROR

Memory used to retain settings on Load Sensing System Mod-
ule has been corrupted and must be reset by verifying all
entries / re-calibrating.
9-2 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“EEPROM ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL]. Retained until power is re-cycled.
Vehicle assumed to be Overloaded

After resolution, re-cycle power
to clear difficulty.

9 3

LSS HAS NOT BEEN CALIBRATED

9-3 Flash Code
The Load Sensing System’s Calibration EEPROM for Empty Plat-
form Load is set to Never Set (signature implanted by the In-
Circuit Test Fixture) AND [Machine Setup’s LOAD is set to
1=CUTOUT PLT OR 2=CUTOUT ALL]. Retained until Calibration
EEPROM is over-written by a valid calibration.
Vehicle assumed to be Overloaded.

Calibrate the Load Sensing Sys-
tem using the calibration proce-
dure to clear the message.

Table 5-2. Flash Code Listing

Flash

Code

Help Message

Cause

Possible Resolve

Advertising
This manual is related to the following products: