4 operation, Operation -7 – JLG 41AM Operator Manual User Manual

Page 17

Advertising
background image

SECTION 1 - SAFETY PRECAUTIONS

3121211

– JLG Lift –

1-7

Maintain a clearance of at least 10 ft (3m) between any part of
the machine and its occupants, their tools, and their equip-
ment from any electrical line or apparatus carrying up to
50,000 volts. One foot (0.3m) additional clearance is required
for every additional 30,000 volts or less.

The minimum approach distance may be reduced if insulat-
ing barriers are installed to prevent contact, and if the barriers
are rated for the voltage of the line being guarded. These bar-
riers shall not be part of (or attached to) the machine. The min-
imum approach distance shall be reduced to a distance within
the designed working dimensions of the insulating barrier.
This determination shall be made by a qualified person in
accordance with employer, local, or governmental require-
ments for work practices near energized equipment.

1.4

OPERATION

Do not operate any machine on which instruction placards

or decals are missing or illegible.

Never exceed the maximum platform capacity.

Operate AC units with an extension cord rated at a mini-

mum of 15 amps.

Prior to entering the platform ensure all leveling jacks have

been properly installed and the unit’s base frame is level
according to the bubble leveling indicator on base frame,
and all wheels are completely off the ground.

While operating the machine, always look in the direction

of machine movement.

Never operate a machine that is not operating properly. If a

malfunction occurs, shut down the machine.

When applicable by reason of local regulations or job-site/

employer safety rules, personnel in the platform shall at all
times wear approved fall protection devices. The autho-
rized lanyard attachment is on the side of the machine’s
mast.

Advertising