SECTION 4 - MACHINE OPERATION

3121205

– JLG Lift –

4-13

4.12 AUXILIARY POWER - NON ADE EQUIPPED

MACHINES

WHEN OPERATING ON AUXILIARY POWER, DO NOT OPERATE MORE
THAN ONE FUNCTION AT A TIME. (SIMULTANEOUS OPERATION CAN
OVERLOAD THE 12-VOLT AUXILIARY PUMP MOTOR.)

A toggle type auxiliary power control switch is located on the
platform control station and another is located on the ground
control station. Operation of either switch turns on the electri-
cally driven auxiliary hydraulic pump. This should be used in
case of failure of the main power plant. The auxiliary pump
will operate boom lift, telescope and swing. To activate auxil-
iary power:

Activating from the Platform Control Station

1. Position PLATFORM/GROUND SELECT KEY SWITCH to

PLATFORM.

2. Position POWER/EMERGENCY STOP switch to ON.

3. Depress and hold footswitch.

4. Operate appropriate control switch, lever or controller

for desired function and hold.

5. Position AUXILIARY POWER switch to ON and hold.

6. Release AUXILIARY POWER switch, selected control

switch, lever or controller, and footswitch.

7. Position POWER/EMERGENCY STOP switch to OFF.

Activating from the Ground Control Station

1. Position PLATFORM/GROUND SELECT KEY SWITCH to

GROUND.

2. Position POWER/EMERGENCY STOP switch to ON.

3. Operate appropriate control switch or controller for

desired function and hold.

4. Position AUXILIARY POWER switch to ON and hold.

5. Release AUXILIARY POWER switch, and appropriate

control switch or controller.

6. Position POWER/EMERGENCY STOP switch to OFF.