Section 1. specifications, 1 capacities, Hydraulic oil reservoir – JLG 19AMI Service Manual User Manual

Page 11: 2 component data, Hydraulic pump/electric motor assembly, Batteries - dc models, Battery charger - dc models, 3 performance data, Platform capacity (max. rated load), Machine speeds

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121190

– JLG Lift –

1-1

SECTION 1. SPECIFICATIONS

1.1 CAPACITIES

Hydraulic Oil Reservoir

DC Models – 5 qts. U.S. (4.7 ltr.)

1.2 COMPONENT DATA

Hydraulic Pump/Electric Motor Assembly

DC Models - 12 Volt DC motor/pump

Motor - 12v - DC Standard Duty

Pump Displacement – .098 cu. in./rev.(AFC 1.6 cc/rev.)

Pump Output – 1.42 GPM @ 800 PSI @ 11.7v-DC @

135 AMPS @ 45 Centistrokes (200

SSU)

Pressure Relief – Adjustable Range 1500 to 3500 PSI,

Set to 2800 PSI (193 bar) at fac-

tory

Batteries – DC Models

WET (Standard)

12 Volt - 165 Amp (min.) - Deep Cycle Marine - RV -
80 lbs.

DRY (Option)

12 Volt – 165 Amp (min.) – Deep Cycle Marine - RV -
80 lbs.

AGM (Absorption Gas Mat) (Option)

12Volt – 100 O.A.H. – M2 Marine Combination -
104 lbs.

Battery Charger – DC Models

110/240 Volts AC, 50/60 Hz - input

12 Volt DC, 10 Amp - output

Automatic SCR Charger

Selectable Voltage

NOTE: A high output - 12Volt DC, 20 Amp output - SCR

charger is supplied with the AGM battery option.

1.3 PERFORMANCE DATA

Platform Capacity (max. rated load)

19AMI - 350 lb.* (160kg) - ANSI-U.S.A./Latin America

* Evenly distributed on platform floor.

Machine Speeds

19AMI - Lift up - 34 seconds *

Lift down - 18 to 25 seconds *

*Timed with maximum rated load: 350 lb. (160kg)

Machine Weight

(w ith S tan dard Platfo rm )

19AMI - 1,130 lbs. (513 kg)

Machine Height

(Platfo rm S tow ed)

19AMI - 78 in. (1.98 m)

Maximum Platform Height

(Mas t F u lly E x ten ded)

19AMI - 19 ft. 1 in. (5.8m)

Maximum Working Height

(A v erag e pers o n )

19AMI - 25 ft. (7.62m)

Machine Overall Width and Length (

B

as e)

19AMI - 34 in.(W) x 55 in.(L)

(86.3 cm x 139.7 cm)

1.4 TORQUE REQUIREMENTS

When maintenance becomes necessary or a fastener has
loosened, refer to the Torque Chart, Figure 1-2. to deter-
mine proper torque value per fastener size and thread
type.

Advertising