3.11 DC TO AC INVERTER OPERATION (OPTION)

1.

The AC inverter ON/OFF toggle switch (1) is located on the
machines’ ground control panel (2).

2.

When the toggle switch is set to the ON position this will
allow AC current from the inverter to flow to the inverter AC
extension cable plug located at the right rear of the
machine.

The platform AC receptacle box extension cable plug, also
located at the rear of the machine can be plugged into the
inverter AC extension cable, or a device can be plugged
directly into the inverter AC cable at this point.

NOTE:

Turn off any device before connecting to inverter AC circuit. Con-
nect devices one at a time to the AC receptacle box. Do not con-
nect to many high-surge devices at once.

NOTICE

IF INVERTER SWITCH IS LEFT ON AND EMERGENCY STOP BUTTON IS NOT
PUSHED IN, POWER WILL DRAIN FROM THE BATTERIES.

3.

To turn off the AC current to the platform AC receptacle box,
set the inverter toggle switch to the OFF position.

NOTE:

The inverter audible alarm may make a momentary chirp when
the inverter is turned OFF. This same alarm may also sound
when the inverter is being connected to or disconnected from
the 24 volt battery bank.

NOTE:

Further General and Troubleshooting information about the
Inverter can be found in the Service Manual for this machine.

Figure 3-13. Location of AC Inverter ON/OFF - Toggle

Switch

1. Inverter ON/OFF Switch

2. Ground Control Panel

INVERTER

ON

OFF