1 power-up, 2 platform controls, 1 power-up -19 – JLG 3248RS/10RS Operator Manual User Manual

Page 83: 2 platform controls -19

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

3121272

– JLG Lift –

5-19

2-1 Power-Up

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

211

POWER CYCLE

This help message is issued at each power
cycle. Displays on the analyzer only.

Normal operation. No check necessary.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

221

FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED

The horn switch was closed during power-up
in platform mode.

Check if the horn switch is damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.

223

FUNCTION PROBLEM - DRIVE & LIFT
ACTIVE TOGETHER

The drive and lift inputs are closed simultane-
ously in platform mode.

Check drive/lift switch for visible damage.
Refer problem to a qualified JLG mechanic.

224

FUNCTION PROBLEM - STEER LEFT PER-
MANENTLY SELECTED

The steer left switch was closed during power-
up in platform mode.

Check if the steer left switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

225

FUNCTION PROBLEM - STEER RIGHT
PERMANENTLY SELECTED

The steer right switch was closed during
power-up in platform mode.

Check if the steer right switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

226

ACCELERATOR FAULTY - WIPER OUT OF
RANGE

There is a problem with the joystick.

Center joystick and check to see if a power cycle will clear DTC.
Refer problem to a qualified JLG mechanic.

227

STEER SWITCHES FAULTY

The steer left and steer right inputs were
closed simultaneously.

Check if the steer switches are damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.

Advertising
This manual is related to the following products: