SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-20

– JLG Lift –

3121272

228

FUNCTION LOCKED OUT - ACCELERATOR
NOT CENTERED

The joystick was not centered at power-up.

Release joystick and allow to center.
Check if the joystick is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

229

FUNCTION PROBLEM - TRIGGER PER-
MANENTLY CLOSED

The trigger switch was closed during power-
up in platform mode.

Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

2210 TRIGGER CLOSED TOO LONG WHILE IN

NEUTRAL

The trigger switch was closed for more than
five seconds while the joystick was centered.

Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

2232 FUNCTION PROBLEM - DRIVE & LIFT

BOTH OPEN

The drive and lift inputs are both de-energized
in platform mode.

Check if either function is active, if Yes;

Refer problem to a qualified JLG mechanic.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

2-3 Ground Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

231

FUNCTION PROBLEM - LIFT PERMA-
NENTLY SELECTED

The ground control box lift switch was closed
up or down, during power-up in ground mode.

Check if the lift switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

232

GROUND LIFT UP / DOWN ACTIVE
TOGETHER

The lift up / down inputs are closed simultane-
ously.

Check if the lift switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.

233

FUNCTION PROBLEM - BRAKE RELEASE
PERMANENTLY SELECTED

The electric brake release switch was closed
during power-up.

Check if the brake release switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.