SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

3121272

– JLG Lift –

5-27

7711 PUMP P LOW - CHECK POWER CIRCUITS The power module detected a problem in the

drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

7741 ARMATURE BRAKING CURRENT TOO

HIGH

The power module has detected excessive
braking current.

This can be caused by transporting an excessive load on a steep grade.

7742 FIELD VOLTAGE IMPROPER

The power module detected a problem in the
drive motors' power circuit wiring.

Recycle power on/off, if problem persists;
Refer problem to a qualified JLG mechanic.

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8-2 LSS - Load Sensing System

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8212 LSS PRESSURE SENSOR -

DISAGREEMENT

Pressure Sensor 1 and Pressure Sensor 2 do not
agree. The system shall assume the machine is
overloaded until the sensors agree.

Refer problem to a qualified JLG mechanic.

8213 LSS ANGLE SENSOR -

DISAGREEMENT

The angle sensor’s change in reading does not
agree with the direction of themachine
motion (lift up).

Refer problem to a qualified JLG mechanic.

8214 LSS ANGLE SENSOR -

DIRECTION DISAGREEMENT

The angle sensor’s reading when the machine
is at maximum elevation does not fall within
the high end acceptable range.

Refer problem to a qualified JLG mechanic.