Abnormal cycle indicator led, Abnormal cycle indicator led -4 – JLG 15SP Operator Manual User Manual

Page 38

Advertising
background image

SECTION 4 - MACHINE OPERATION

4-4

– JLG Lift –

3120774

2. Connect the battery charger AC power cord receptacle

to a properly grounded AC electrical outlet, use a suit-
able extension cord.

3. When plugged in, the charger runs through a self-diag-

nostic check. The LED’s on the front panel of the battery
charger flash in the sequence.

4. When ready to charge, the CHARGER ON LED and the

INCOMPLETE CHARGE (25%) LED on the front panel of
the charger will light up, the charger will then begin to
charge the batteries.

NOTE: If the ABNORMAL CYCLE LED comes on and stays on at

any time during the charge cycle, see sub-section follow-
ing about the ABNORMAL CYCLE indicator LED.

5. When the battery cell voltage reaches 2.37 V/cell the

80% CHARGE LED on the front panel of the charger will
light up. The charger then continues to monitor the
increase in charge until it sees no increase, and then ter-
minates the charging process.

6. The CHARGE COMPLETE (100%) LED will come on

when the charging process is finished.

7. Remove the power cord from the AC power cord recep-

tacle on the face of the charger.

Abnormal Cycle Indicator LED

If the ABNORMAL CYCLE indicator LED should come on during
the normal charging cycle of the batteries, it could indicate any of
the following conditions;

• The AC input to the charger was interrupted, i.e. local

power failure or charger cable was unplugged or bumped
and power was interrupted intermittently.

• A dead cell or cells in the battery would prevent the charger

from sensing enough voltage to complete the battery
charge.

• One or more of the battery terminal connections loose or

corroded resulting in an intermittent incomplete circuit.