M

OUNTING PROCEDURE

•

Use the drilling template to drill holes according the mounting illustration in the
control panel with the specified threading.

•

Insert the upper screws half way into the control panel and hang the device on the
mounting links.

•

Tighten the screws and insert the rest of the screws.

Note:
The device is connected to the power supply using a lead out terminal with a screw

connection. A ground connection does not have to be made, because the grounding

conductor of the device plug or supply connection serves this purpose. If additional

grounding conductors are attached to a grounding screw, a wire diameter of at least 2.5

mm² is specified.