3 – diagnostic mode – AiM Yamaha R6 User Manual
Page 18

MXL Plug&Play kit for Yamaha R1 2004/2005/2006 – R6 2004/2005/
User manual
Release 1.01
17
www.aim-sportline.com
5
4.3 – Diagnostic mode
It allows to monitor the behaviour of sensors and signals out coming from the ECU. It is
possible to switch from Running mode to diagnostic mode when the engine is off.
To enter Diagnostic Mode from Running Mode press first “MENU/<<” and “VIEW/QUIT” at
one time and then “MENU/<<” e “>>”.Diagnostic mode will show information concerning
different sensors in different pages. Use “MENU/<<” and “>>” to scroll through the pages.
The table here below shows the pages.
Page Description Shown
data
THROTTLE SENSOR
Master throttle angle
Valve open angle (from 0° to
125°).
ATMO PRESSURE
Atmospheric pressure Atmospheric pressure in Kpa.
INTAKE PRESSURE
Intake air pressure.
AirBox pressure in Kpa.
INTAKE TEMP
Intake air temperature. Intake air temperature in °C.
WATER TEMP
Water temperature
Water temperature in °C
VEHICLE SPEED
Vehicle speed. Shows
incremental number of
pulses read by the
sensor.
Reads pulses form 0 to 99.
OVERTURN SENSOR
Value read by the anti-
overturn sensor.
Voltage value*10 (from 0 to 50)
BATTERY VOLTAGE
Battery voltage
Battery voltage
SWITCH (STOCK BIKE)
Switch (stock)
1 = OFF (stock on)
0 = OFF (stock off)
SWITCH (YEC KIT)
Switch (ECU kit)
1 = ON
0 = OFF
SELECT SWITCH (STOCK
BIKE)
Neutral Switch
1 = Neutral
0 = Gear
SELECT SWITCH (YEC
KIT)
Map selection switch
(kit YEC)
1 = SB
0 = ST
IGNITION COIL 1
When engine-off switch is selected and de-selected the
engine off switch turns the coil on 5 times (shown value is
not important).
IGNITION COIL 2
IGNITION COIL 3
IGNITION COIL 4
INJECTOR 1
When engine-off switch is selected and de-selected the
engine off switch turns the injector on 5 times (shown value
is not important).
INJECTOR 2
INJECTOR 3
INJECTOR 4
AI SOLENOID (STOCK
only)
When engine-off switch is selected and de-selected the
engine off switch turns the AI Solenoid on 5 times.
MAIN RELAY
When engine-off switch is selected and de-selected the
engine off switch turns the main relay on 5 times (shown
value is not important).
FAN RELAY (STOCK only)
When engine-off switch is selected and de-selected the
engine off switch turns the fan relay on 5 times.
PROJECTOR RELAY
When engine-off switch is selected and de-selected the
engine off switch turns the projector relay on 5 times.