Appendix A: Alarm I/O Connector
Some features of the Network Camera can be activated by the external sensor that senses 
physical changes in the area Network Camera is monitoring. These changes can include 
intrusion detection or certain physical change in the monitored area. For examples, the 
external sensor can be a door switch or an infrared motion detector. These devices are 
customer provided, and are available from dealers who carry surveillance and security 
products. Electrically, they must be able to provide a momentary contact closure. 
 
This device provides a general I/O terminal block with one digital input and one output for 
device control. The pin 1 is located at the right side of terminal block from rear view. Pin 2 
and 3 can be connected to an external sensor. The input voltage will be monitored from the 
initial state ‘LOW’. If the external sensor need 12VDC power, it can connect to Pin1 (50mA 
maximum). The Alarm Output of pin 3 and 4 can be used to turn on or off the external 
device. 
 
This Network Camera provides a general I/O terminal block as below: 
 
Name
Cable Color
Function
12VDC Brown/White
DC 12V (50mA maximum)
GND Blue/White GND 
D+ 
Purple/White RS485 data +
D-
Gray
RS485 data -
DI
Green/White
Digital signal input
DO
Orange/White Digital signal output
 
User can refer to the schematic below to make a proper connection between I/O connector 
and external sensor and output device.