Resetting the PL-12

To reset the controller to the default settings

shown in the table below, press and hold the

V

(down) and

U

(up) keys while

powering up the system. Do this by switching on the GR2 or by plugging in
the PL-12 CAT5 cable TO GR2 connection while the GR2 is on. Keep the key
pressed while the 4 source indicators flash red, the 8 level indicators count
down one at a time, and finally the source indicators flash green to confirm the
reset. Releasing the keys before the sequence finishes cancels the reset.

PL-12 option menu

Access using the front panel keys.

Enter and exit setup Press and hold the

V

(down) key for 4 seconds to enter

setup mode. The 4 source indicators light orange until an option is selected by
turning the rotary. Keep the

V

key held down while changing the settings.

To save the settings and return to normal operating mode release the key.

Option select Turn the rotary control to scroll through the 8 available options.
The current option number is displayed on the LED indicator bar above.
Parameter display The current setting for the selected option is displayed on
the 4 LED indicators.

Change parameter While holding the

V

key, tap the

U

(up) key to cycle

through the available parameters. These are detailed in the table below.

Working with presets

The optional PL-5 infra-red hand-held

controller adds the presets function. Up to 4 level and source selection
combinations may be stored in the PL-12 memory. This is convenient for quick
recall of settings for regular events. The installer can store these during
installation, then use menu option 7 to disable store to prevent them being
overwritten by the operator. To disable preset recall use menu option 6.

To store a preset Select the required source and level. Hold down the
required PL-5 preset key for 4 seconds. The PL-12 source indicators all flash
green to confirm the store.

To recall a preset Briefly press and release the required PL-5 preset key.

Important: Observe the local standards which

may apply to the installation. To ensure operator
safety ensure that exposed metal plates are correctly
bonded to ground. Do not install the equipment
where it is subject to moisture, heat or vibration.

Warning: To avoid damage, connect the PL-12

to the Allen & Heath GR2 only. This product is not
compatible with the Allen & Heath PL-Anet system.

To avoid damage to the equipment, make sure

all wiring is inspected and continuity tested before
powering up the system.

NOTE: Do not install the PL-12 in a position subject
to bright sunlight as this may reduce the effectiveness
of the IR signal. Note that if you have two PL-12 in
one room they may both pick up the signal from one
IR controller. This may or may not be desired.

This product complies with the European

Electromagnetic Compatibility directives

89/336/EEC & 92/31/EEC.

NOTE: Any changes or modifications to the equipment not

approved by Allen & Heath could void the compliance of the

equipment. Whilst we believe the information in this guide to

be reliable we do not assume responsibility for inaccuracies.

We also reserve the right to make changes in the interest of

further product development. Copyright© 2005 Allen & Heath

Ltd. All rights reserved.

PRESET

KEYS

HEATH

ALLEN

&

DISPLAY

8

7

6

5

4

3

2

1

4

3

2

1

PARAMETER

CHANGE

OPTION

OPTION

NUMBER

SELECT

PARAMETER

DISPLAY

ENTER

SETUP

8

7

6

5

4

3

2

1

4

3

2

1

HOLD

2 = COUNTS DOWN

1 = FLASHES RED

3 = FLASHES GREEN

POWER UP

+

OPTION

LED 1

LED 2

LED 3

LED 4

COMMENT

Off, On

Red = Off

Can only be set on the zone 1 controller

Gn = On

2

Sources to select

123, 234, 23, 0, 1234

music 1

music 2

music 3

music 4 Cycle through the available options

Off, On

Red = Off

Adds a 'no source' selection

Gn = On

4

Power up default

Last, Off, Preset

Last

Off

Preset

The source selection and level on power up

5

Power up preset

1, 2, 3, 4

preset 1

preset 2

preset 3

preset 4 Which preset shall be recalled on power up (if set in option 4)

Off, On

Red = Off

Enables preset recall from the PL-5 IR controller

Gn = On

Off, On

Red = Off

Enables preset store from the PL-5 IR controller

Gn = On

8

Follow mode

Source, Source+Level

Source

Level

Which zone 2 parameter follows the zone 1 controller
Must be set the same on both zone 1 and 2 controllers

Reset defaults shown in bold above

7

Zone 2 follow Zone 1

Source off position

PL-5 preset recall

PL-5 preset store

1

3