Chapter 4. maintenance, 1 general caution during maintenance, 2 check list and periodic maintenance – AMMCO AC1000M Motorcycle Lift User Manual

Page 17: 1 general caution during maintenance -17, 2 check list and periodic maintenance -17, Maintenance interval chart, Chapter 4, Maintenance

Advertising
background image

Model: AC1000M

Installation, Operation & Maintenance

17

CHAPTER 4.

MAINTENANCE

4-1 General caution during

maintenance

1) Two or more persons should perform

maintenance.

2) Maintenance should be carried out after

putting a signboard of "NO ENTRANCE"

at work area.

3) Do not disassemble the system before

you are familiar with the disassembling

sequence.

4) Record the place or parts where

maintenance is needed.

5) Keep disassembled parts stored where

they can be easily accessed.

6) Be sure to fasten bolts and nuts position

correctly during assembly.

7) During maintenance, verify locks are in

“engaged” position.

8) Inspect air lines and fittings at least once

a month.

9) Check weekly for loose nuts and bolts.

Retighten if needed.

4-2 Check List and periodic maintenance

Maintenance Interval Chart

The following chart should be considered strictly as a guide to general maintenance intervals. Depending
on operating conditions, the intervals of maintenance should be changed.

Initial Thereafter

Every Part#

10 hours

25 hours

50 hours

100 hours 200 hours

Maintenance

Interval

Item

1 month

3 months

6 months

12

months

24

months


Bolts Inspect

X X

603

Pivot Pin

Inspect

X

X

13, 14, 20

Pivot Pin
Circlip

Inspect,
Replace

X X

608,

609

Lubrication
Points

Lubricate X X X X

Drop

Panels

Inspect

X X 2

Sliding Lock

Inspect

X

X

12

Rollers

Inspect

X X X

16,

17

Cylinder

Inspect

X X X 7

Cylinder Seal

Visually
Inspect

X X X

Bearings

Inspect

X X X

612

Safety Lock
Guide

Inspect

X X X X 18

Locking

Bar

Inspect

X X X X 6

Pedal Inspect

X X X X 22

Air Valve

Inspect

X

X

X

X

23