General maintenance – Autoquip CMD DOCK LIFT User Manual
Page 24

24
WIRING THE MOTOR
Use the following chart in connecting these motors to power sources.
HP and Source
AMP Draw
(full load)
2 HP / 115 V/60 CY/1 PH
22 A
2 HP / 230 V/60 CY/1 PH
11 A
NOTE: 115V/1ph/60Hz operation is not recommended. If 115V/1ph operation is
absolutely required, the lift will function properly if adequate power is supplied.
However, it is very sensitive to deviations from the required power. Consequently,
performance could prove unsatisfactory. To assure proper operation on 115V/1ph/60Hz
power supply, a separate circuit, protected by a 30 AMP time delay circuit breaker, and
adequate wiring should be provided to allow and actual 115V at the power cord plug
during fully loaded operation. Specify if required.
MOTOR CONNECTION DIAGRAMS
GENERAL MAINTENANCE