Table 1. System Programming Procedure

STEP ACTION

DISPLAY

COMMENTS

1 Press

the

FILTER/OFF/FRY

switch to FRY.

LOW

2

Press PROG on the keypad.

PROGRAM CODE

3

Input 1712 and ENTER.

PROGRAM SYSTEM

4 Press

ENTER.

PROGRAM

DEGREES

F

This command allows you to
choose the temperature scale
option you want to use. The display
will show either show

F or C.

5

Press TOGGLE/CLEAR until the
desired option is displayed.

PROGRAM DEGREES

X

X refers to the temperature scale
you have chosen.

6

Press ENTER.

PROGRAM APL TYPE

GAS

This command allows you to
choose the appliance type you are
using. The display may show
ELECTRIC, GAS OR ALF.

7

Press TOGGLE/CLEAR until the
desired option is displayed.

PROGRAM APL TYPE

X

X refers to the appliance type you
have chosen.

8 Press

ENTER.

PROGRAM

MELTCYCL

YES

This command allows you to set
the melt cycle option. This is
normally set to yes if you are using
solid shortening. The display will
show either YES or NO.

9

Press TOGGLE/CLEAR until the
desired option is displayed.

PROGRAM MELTCYCL

X

X refers to the melt cycle option
chosen.

10 Press

ENTER.

PROGRAM

GLBLFLTR

0

This command allows you to
specify the total number of fry
cycles to complete among all
product programs before a
message is displayed reminding
you to filter the shortening (filter
lockout).

11

Press TOGGLE/CLEAR and
input the number of fry cycles
you want to complete among all
product programs before
enabling filter lockout.

PROGRAM GLBLFLTR

X

X refers to the number of program
cycles you want to complete
among all product programs before
filtering the shortening.

12

Press ENTER.

PROGRAM SYSTEM

13

Press PROG to exit the
programming mode.

LOW