ClearPAGE Precast Gel Running Instructions 7-1-14

2

GENERAL INSTRUCTIONS

1) Use ONLY ClearPAGE buffers with ClearPAGE TEO gels. Ordering

information for these reagents is on pages 12-14. Alternatively, you can

make your own by following the buffer formulations on pages 9-10.

2) The running and loading buffers must be consistent with the type of gel being

used (SDS PAGE or DNA/Native)

3) Do not substitute or mix reagents with those from other sources.

4) Use only ultrapure water for washing and dilution purposes.

5) These products should only be used by qualified personnel who have had

laboratory safety instruction.

6) The complete instructions should be read and understood before attempting to use

the product.

7) Products should be used before the “Best by” date on the product label.

8) Wear gloves at all times when handling gels, buffers, etc.

9) Before running first gel in the DCX-700, QNC-700 or QNX-700 please read

the Dual Cool/Quadra Instruction manual for important safety and general use

instructions. To open DualCool/Quadra, push thumbs down on white/clear posts

while pulling lid up with fingers as shown on right. DO NOT PULL UP ON

LEADS!

RUNNING BUFFER PREPARATION

Type of Gel

Running Buffer Cat. #’s

Dilution factor

ClearPAGE Neutral pH -TEO SDS-Non-Reducing: (cat. # FB50053 or FB50500)

SDS-Reducing: (cat. # FB60053 or FB60500)

Turbo SDS: (cat.# CB13500)

20X

20X

20X

DNA/Native

DNA/Native: (cat. # GB61053 or GB61500)

20X

ClearPAGE™ SDS or ClearPAGE DNA/NATIVE Running Buffers MUST be

used to run these gels. To make 1 liter of 1x running buffer (for example: dilute

50ml 20x Running Buffer with 950ml ultrapure water or dilute 100mls of 10X

buffer with 900mls of ultrapure water) for a run. For the ClearPAGE Running

Buffer bottle included in the Sampler Kits, dilute by adding its contents to 950ml

ultrapure water. Remember, to save time and money you can use reconstituted

ClearPAGE running buffer for the bottom reservoir by following instructions

below:

RECYCLING BUFFER INSTRUCTIONS: The buffer may be reused on the

anode side, but fresh buffer is ALWAYS required in the cathode chamber. When

reusing buffer make sure used buffer from upper core gets recycled as well. This

can be accomplished by removing the gel cassettes while the core is still in the

unit and letting the buffer drain into the lower chamber. Pour this reconstituted

buffer into a separate container for reuse in the anode chamber of your next gel

run! This buffer can be used time and time again. For fresh upper core buffer

dilute 10 ml of ClearPAGE™ Running Buffer (20x) to 200 ml with ultrapure

water.

ClearPAGE ™ Gel Running Instructions

FOR USE WITH: C.B.S. Scientific’s Combo 2-place Dual Cool System (DCX-700) and

Combo 4-place Quadra Systems (QNC-700 & QNX-700)

Advertising