1.2.2

Serial Communications Settings

1.2.2.1 Configuration

•

RS-232

•

RS-485 (Default)

1.2.2.2 Data

Bits

•

7 bits

•

8 bits (Default)

The Data Bits setting should match the Transmission Mode as
follows. The ability to set the Data Bits independent of
Transmission Mode is to allow for maximum flexibility.

•

RTU

8 Data Bits

•

ASCII

7 Data Bits

1.2.2.3 Parity

•

EVEN (Default)

•

ODD

•

NONE

1.2.2.4 Stop

Bits

•

1 (Default)

•

2

1.2.2.5 Baud

Rate

•

2400

•

9600 (Default)

•

19200

•

38400

•

57600

•

115200

Note: The Modbus specification requires the use of 2 Stop Bits when
No Parity is selected.